How to use this calculator
Resolve the active soil force on a vertical rough wall when the backfill rises away from the wall.
- Enter Wall height (m), Dry backfill unit weight (kN/m³), Soil friction angle (degrees), Wall friction angle (degrees), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Coulomb active earth thrust for sloping backfill explained
For a vertical retaining wall and sloping cohesionless backfill, Coulomb’s active-wedge model gives the limiting soil thrust after enough wall movement to mobilize the active state. Wall friction tilts the resultant, so horizontal and downward components are reported separately.
Inputs, symbols, and units
H— Wall height (m)- Vertical height of the wall-backfill contact.
g— Dry backfill unit weight (kN/m³)- Total unit weight for this dry drained wedge model.
phi— Soil friction angle (degrees)- Internal drained friction angle; must exceed backfill slope.
delta— Wall friction angle (degrees)- Soil-wall friction angle, limited here to no more than the soil friction angle.
beta— Backfill slope angle (degrees)- Upward backfill inclination measured from horizontal away from the wall.
Formula and method
Ka=cos²φ/{cosδ[1+√(sin(φ+δ)sin(φ−β)/(cosδ cosβ))]²}; Pa=γH²Ka/2 for a vertical wall.
Angles are entered in degrees and converted internally. The resultant acts δ below the horizontal wall normal, so horizontal and downward components are returned.
A worked scenario
Wall height (m) = 5; Dry backfill unit weight (kN/m³) = 18; Soil friction angle (degrees) = 34; Wall friction angle (degrees) = 15; Backfill slope angle (degrees) = 10.
- Active resultant: 65.1116 kN/m
- Coulomb coefficient: 0.289385
- Horizontal component: 62.892976 kN/m
- Downward component: 16.852122 kN/m
For H=5 m, γ=18 kN/m³, φ=34°, wall friction 15° and backfill inclination 10°, the active wedge coefficient differs from the smooth level Rankine value.
Assumptions and edge cases
Planar active Coulomb wedge in dry cohesionless soil, vertical wall and uniform slope. Water, cohesion, wall batter and passive curved failure surfaces are excluded. Educational model; this is not a code-compliant design check.
Reading the outputs
The resultant and its two components are kN/m of wall length; Ka is dimensionless.
Frequently asked questions
Why must β be below φ?
A dry cohesionless slope at or above its friction angle is outside this stable-backfill idealization.
Is the full resultant horizontal?
No. Positive wall friction gives a downward component on this vertical wall.
Can this be used for passive thrust by changing a sign?
No. Passive Coulomb behavior and applicability need their own treatment and are not provided here.
How do I use the Coulomb active earth thrust for sloping backfill calculator?
Enter Wall height (m), Dry backfill unit weight (kN/m³), Soil friction angle (degrees), Wall friction angle (degrees), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Coulomb active earth thrust for sloping backfill?
Wall height (m) = 5; Dry backfill unit weight (kN/m³) = 18; Soil friction angle (degrees) = 34; Wall friction angle (degrees) = 15; Backfill slope angle (degrees) = 10. Active resultant: 65.1116 kN/m Coulomb coefficient: 0.289385 Horizontal component: 62.892976 kN/m Downward component: 16.852122 kN/m For H=5 m, γ=18 kN/m³, φ=34°, wall friction 15° and backfill inclination 10°, the active wedge coefficient differs from the smooth level Rankine value.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume II.
Reference access note: The linked FHWA Volume II PDF was not retrievable during this review. The stated equation and numerical example were checked independently; verify against the manual before using for design.
Read our calculation methodology.