How to use this calculator
Balance an entered retaining-wall force system and locate its base resultant before a separate contact-pressure or bearing-capacity check.
- Enter Vertical stabilizing force (kN/m), Vertical force lever arm from toe (m), Horizontal earth thrust (kN/m), Thrust height above base (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Retaining wall sliding overturning and base resultant explained
Use Vertical stabilizing force (kN/m) with Vertical force lever arm from toe (m) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.
A numerical walkthrough
Vertical stabilizing force (kN/m) = 300; Vertical force lever arm from toe (m) = 1.2; Horizontal earth thrust (kN/m) = 90; Thrust height above base (m) = 1.5; Base width (m) = 2.5; Base friction coefficient = 0.5; Additional specified sliding resistance (kN/m) = 0.
- Sliding resistance ratio: 1.666667
- Overturning moment ratio: 2.666667
- Resultant distance from toe: 0.75 m
- Eccentricity from centre: 0.5 m
A 300 kN/m vertical force 1.2 m from the toe opposes 90 kN/m thrust at 1.5 m height over a 2.5 m base, with μ=0.5.
The model behind the numbers
Sliding ratio=(μW+R)/P; moment ratio=Wx/(Ph); xR=x−Ph/W; e=B/2−xR.
All loads must use a consistent unfactored or factored basis. The calculator does not infer a retaining-wall geometry or choose acceptance thresholds.
What to enter
W— Vertical stabilizing force (kN/m)- Downward force including wall, footing and any intentionally included supported soil.
x— Vertical force lever arm from toe (m)- Horizontal distance from the toe to the vertical force resultant.
P— Horizontal earth thrust (kN/m)- Net horizontal driving force; include all intended soil and water components.
height— Thrust height above base (m)- Vertical lever arm of the horizontal resultant about the toe.
B— Base width (m)- Total width available for compressive foundation contact.
mu— Base friction coefficient- Mobilizable sliding friction coefficient at the base.
R— Additional specified sliding resistance (kN/m)- Explicitly justified resistance such as a separately factored key/passive component; zero avoids relying on it.
Interpreting the result
One horizontal and one combined vertical resultant, no uplift subtraction unless incorporated in W, and no seismic or bearing verification. Educational model; this is not a code-compliant design check.
Reading the outputs
Two dimensionless equilibrium ratios are followed by the resultant position and signed centre eccentricity in m.
Frequently asked questions
Should water under the base reduce W?
Use the net effective vertical resultant and its correct lever arm; uplift distribution cannot be omitted.
Are the displayed ratios design safety factors?
They are force and moment ratios only. Required factors depend on the applicable design framework.
Why is a resultant outside the base rejected?
The simplified foundation cannot maintain compressive equilibrium in that state.
How do I use the Retaining wall sliding overturning and base resultant calculator?
Enter Vertical stabilizing force (kN/m), Vertical force lever arm from toe (m), Horizontal earth thrust (kN/m), Thrust height above base (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Retaining wall sliding overturning and base resultant?
Vertical stabilizing force (kN/m) = 300; Vertical force lever arm from toe (m) = 1.2; Horizontal earth thrust (kN/m) = 90; Thrust height above base (m) = 1.5; Base width (m) = 2.5; Base friction coefficient = 0.5; Additional specified sliding resistance (kN/m) = 0. Sliding resistance ratio: 1.666667 Overturning moment ratio: 2.666667 Resultant distance from toe: 0.75 m Eccentricity from centre: 0.5 m A 300 kN/m vertical force 1.2 m from the toe opposes 90 kN/m thrust at 1.5 m height over a 2.5 m base, with μ=0.5.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume II.
Reference access note: The linked FHWA Volume II PDF was not retrievable during this review. The stated equation and numerical example were checked independently; verify against the manual before using for design.
Read our calculation methodology.