How to use this calculator
Fit the late-time straight portion of an observation-well pumping test rather than estimating aquifer properties from a single point.
- Enter Observation times (days), Observed drawdowns (m), Constant pumping rate (m³/day), Observation-well radius (m). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Cooper Jacob late time aquifer test regression explained
Fit drawdown against log10(elapsed time) over the late straight-line portion of a constant-rate test. The fitted slope estimates transmissivity; the extrapolated zero-drawdown intercept and observation-well radius estimate storativity.
Inputs, symbols, and units
t— Observation times (days)- Positive elapsed pumping times in the late semilog-linear portion of a constant-rate observation-well test. Use comma-separated values in the stated order.
s— Observed drawdowns (m)- Paired drawdowns below the initial head; use a consistent datum. Use comma-separated values in the stated order.
Q— Constant pumping rate (m³/day)- Extraction held constant throughout the selected test segment.
r— Observation-well radius (m)- Distance from pumping well; a separate observation well is needed for a meaningful storage estimate.
Formula and method
Fit s=m log10(t)+b by least squares; T=Q ln(10)/(4πm), t0=10^(−b/m), S=4e^(−γ)Tt0/r².
Select the semilog-linear interval before entering it. The tool also reports max(u), where u=r²S/(4Tt), using the fitted T and S. A conservative late-time screen is u ≤ 0.01 at every entered time. Passing this fitted diagnostic does not certify the conceptual aquifer model.
A worked scenario
Observation times (days) = [1, 2, 5, 10, 20]; Observed drawdowns (m) = [1.6, 1.84, 2.16, 2.4, 2.64]; Constant pumping rate (m³/day) = 500; Observation-well radius (m) = 100.
- Fitted transmissivity: 114.547417 m²/day
- Fitted storativity: 0.000257
- Zero-drawdown intercept time: 0.009991 days
- Semilog slope: 0.799817 m per log10 time cycle
Five observations from 1 to 20 days show drawdown increasing from 1.6 to 2.64 m while 500 m³/day is pumped, observed 100 m away. The fitted maximum u is approximately 0.005609, so this example meets the conservative u ≤ 0.01 screen.
Assumptions and edge cases
Late-time Theis approximation, constant extraction and a confined aquifer with no significant boundaries or well-storage distortion. Single-well storage estimates are not supported. Educational model; this is not a code-compliant design check.
Reading the outputs
Transmissivity is m²/day, storativity and u are dimensionless, intercept time is days and the slope is metres per decade of time. Maximum fitted u occurs at the earliest entered time. A warning leaves the numerical regression visible but does not approve use of its aquifer estimates.
Frequently asked questions
May early-time points be included?
Check u=r²S/(4Tt) with consistent units. This tool screens for fitted u ≤ 0.01 at every entered time and warns otherwise. A curved segment should not be forced into a straight-line fit; even passing the screen does not rule out leakage, boundaries or well storage.
Why can the fitted intercept precede the first observation?
It is the zero-drawdown extrapolation of the late-time straight line, not the measured pumping start.
Does a high-quality straight line prove the conceptual model?
No. Leakage, boundaries and measurement effects must also be assessed against the test setting.
How do I use the Cooper Jacob late time aquifer test regression calculator?
Enter Observation times (days), Observed drawdowns (m), Constant pumping rate (m³/day), Observation-well radius (m). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Cooper Jacob late time aquifer test regression?
Observation times (days) = [1, 2, 5, 10, 20]; Observed drawdowns (m) = [1.6, 1.84, 2.16, 2.4, 2.64]; Constant pumping rate (m³/day) = 500; Observation-well radius (m) = 100. Fitted transmissivity: 114.547417 m²/day Fitted storativity: 0.000257 Zero-drawdown intercept time: 0.009991 days Semilog slope: 0.799817 m per log10 time cycle Five observations from 1 to 20 days show drawdown increasing from 1.6 to 2.64 m while 500 m³/day is pumped, observed 100 m away. The fitted maximum u is approximately 0.005609, so this example meets the conservative u ≤ 0.01 screen.
Background or definition reference: USGS aquifer-test theory and interpretation.
Reference access note: The linked USGS aquifer-test reference could not be retrieved. The stated model equation and example were checked independently; consult the primary document before applying to a field test.
Read our calculation methodology.
Model and small-u criterion: The Groundwater Project, Theis and Cooper–Jacob analysis. Uses a conservative small-u screen; fitting a straight line alone does not establish aquifer assumptions.