CalcWorldHub
Free online calculator · no signup

Cooper Jacob late time aquifer test regression calculator

Fit the late-time straight portion of an observation-well pumping test rather than estimating aquifer properties from a single point.

4,000 tools
Cooper Jacob late time aquifer test regression calculator — Observation times (days), Observed drawdowns (m), Constant pumping rate (m³/day) and calculation method
Cooper Jacob late time aquifer test regression calculator: inputs and calculation method.

How to use this calculator

Fit the late-time straight portion of an observation-well pumping test rather than estimating aquifer properties from a single point.

  1. Enter Observation times (days), Observed drawdowns (m), Constant pumping rate (m³/day), Observation-well radius (m). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Cooper Jacob late time aquifer test regression explained

Fit drawdown against log10(elapsed time) over the late straight-line portion of a constant-rate test. The fitted slope estimates transmissivity; the extrapolated zero-drawdown intercept and observation-well radius estimate storativity.

Fitted transmissivity114.5474m²/day
Fitted transmissivity: 114.547417 m²/day in the worked scenario.

Inputs, symbols, and units

t — Observation times (days)
Positive elapsed pumping times in the late semilog-linear portion of a constant-rate observation-well test. Use comma-separated values in the stated order.
s — Observed drawdowns (m)
Paired drawdowns below the initial head; use a consistent datum. Use comma-separated values in the stated order.
Q — Constant pumping rate (m³/day)
Extraction held constant throughout the selected test segment.
r — Observation-well radius (m)
Distance from pumping well; a separate observation well is needed for a meaningful storage estimate.

Formula and method

Fit s=m log10(t)+b by least squares; T=Q ln(10)/(4πm), t0=10^(−b/m), S=4e^(−γ)Tt0/r².

Select the semilog-linear interval before entering it. The tool also reports max(u), where u=r²S/(4Tt), using the fitted T and S. A conservative late-time screen is u ≤ 0.01 at every entered time. Passing this fitted diagnostic does not certify the conceptual aquifer model.

A worked scenario

Observation times (days) = [1, 2, 5, 10, 20]; Observed drawdowns (m) = [1.6, 1.84, 2.16, 2.4, 2.64]; Constant pumping rate (m³/day) = 500; Observation-well radius (m) = 100.

  • Fitted transmissivity: 114.547417 m²/day
  • Fitted storativity: 0.000257
  • Zero-drawdown intercept time: 0.009991 days
  • Semilog slope: 0.799817 m per log10 time cycle

Five observations from 1 to 20 days show drawdown increasing from 1.6 to 2.64 m while 500 m³/day is pumped, observed 100 m away. The fitted maximum u is approximately 0.005609, so this example meets the conservative u ≤ 0.01 screen.

Assumptions and edge cases

Late-time Theis approximation, constant extraction and a confined aquifer with no significant boundaries or well-storage distortion. Single-well storage estimates are not supported. Educational model; this is not a code-compliant design check.

Reading the outputs

Transmissivity is m²/day, storativity and u are dimensionless, intercept time is days and the slope is metres per decade of time. Maximum fitted u occurs at the earliest entered time. A warning leaves the numerical regression visible but does not approve use of its aquifer estimates.

Frequently asked questions

May early-time points be included?

Check u=r²S/(4Tt) with consistent units. This tool screens for fitted u ≤ 0.01 at every entered time and warns otherwise. A curved segment should not be forced into a straight-line fit; even passing the screen does not rule out leakage, boundaries or well storage.

Why can the fitted intercept precede the first observation?

It is the zero-drawdown extrapolation of the late-time straight line, not the measured pumping start.

Does a high-quality straight line prove the conceptual model?

No. Leakage, boundaries and measurement effects must also be assessed against the test setting.

How do I use the Cooper Jacob late time aquifer test regression calculator?

Enter Observation times (days), Observed drawdowns (m), Constant pumping rate (m³/day), Observation-well radius (m). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Cooper Jacob late time aquifer test regression?

Observation times (days) = [1, 2, 5, 10, 20]; Observed drawdowns (m) = [1.6, 1.84, 2.16, 2.4, 2.64]; Constant pumping rate (m³/day) = 500; Observation-well radius (m) = 100. Fitted transmissivity: 114.547417 m²/day Fitted storativity: 0.000257 Zero-drawdown intercept time: 0.009991 days Semilog slope: 0.799817 m per log10 time cycle Five observations from 1 to 20 days show drawdown increasing from 1.6 to 2.64 m while 500 m³/day is pumped, observed 100 m away. The fitted maximum u is approximately 0.005609, so this example meets the conservative u ≤ 0.01 screen.