CalcWorldHub
Free online calculator · no signup

Theis drawdown from stepped pumping history calculator

Predict observation-well drawdown and recovery from several pumping-rate changes using temporal superposition of confined-aquifer responses.

4,000 tools
Theis drawdown from stepped pumping history calculator — Pumping rate after each step (m³/day), Step start times (days), Observation radius (m) and calculation method
Theis drawdown from stepped pumping history calculator: inputs and calculation method.

How to use this calculator

Predict observation-well drawdown and recovery from several pumping-rate changes using temporal superposition of confined-aquifer responses.

  1. Enter Pumping rate after each step (m³/day), Step start times (days), Observation radius (m), Aquifer transmissivity (m²/day), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Theis drawdown from stepped pumping history explained

Superpose Theis well-function contributions for each pumping-rate change to estimate confined-aquifer drawdown at a chosen radius and time.

Net pumping drawdown0.3246m
Net pumping drawdown: 0.324632 m in the worked scenario.

A numerical walkthrough

Pumping rate after each step (m³/day) = [500, 800, 0]; Step start times (days) = [0, 1, 3]; Observation radius (m) = 100; Aquifer transmissivity (m²/day) = 250; Confined storativity = 0.0005; Observation time (days) = 4.

  • Net pumping drawdown: 0.324632 m
  • Time parameter since history origin: 0.00125

Pumping starts at 500 m³/day, rises to 800 on day 1 and stops on day 3. At a 100 m observation radius the day-4 result includes both drawdown history and one day of recovery.

The model behind the numbers

s(r,t)=ΣΔQj E1[ r²S/(4T(t−tj)) ]/(4πT), summed only over tj<t; ΔQj is each rate change.

Input the rate in effect after every step, including shutdown. The calculation converts those levels to signed increments, so recovery emerges from a negative rate change.

What to enter

Q — Pumping rate after each step (m³/day)
Enter absolute extraction rates starting at each step time; zero denotes shutdown. Pair each rate with one time.
ts — Step start times (days)
Enter matching elapsed days in strictly increasing order. Rate changes are calculated from successive absolute rate levels.
r — Observation radius (m)
Distance from the fully penetrating pumping well to the observation point.
T — Aquifer transmissivity (m²/day)
Constant hydraulic conductivity times confined saturated thickness.
S — Confined storativity
Dimensionless volume released per unit aquifer area and head decline.
t — Observation time (days)
Time since the common pumping-history origin.

Interpreting the result

Infinite homogeneous confined aquifer, negligible wellbore storage, fully penetrating well and linear drawdown response. Boundary effects and unconfined dewatering are excluded. Educational model; this is not a code-compliant design check.

Reading the outputs

Net drawdown is m below the initial head. The second result is dimensionless u based on time since the history origin, not each individual step.

Frequently asked questions

Should shutdown be a negative rate?

No. Enter zero as the new rate; the tool forms the negative change internally.

Does a future step affect the current answer?

No. Only changes strictly before the observation time contribute.

Is drawdown at the pumping well itself supported?

No. Radius must be positive and the ideal zero-radius solution omits well losses and well storage.

How do I use the Theis drawdown from stepped pumping history calculator?

Enter Pumping rate after each step (m³/day), Step start times (days), Observation radius (m), Aquifer transmissivity (m²/day), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Theis drawdown from stepped pumping history?

Pumping rate after each step (m³/day) = [500, 800, 0]; Step start times (days) = [0, 1, 3]; Observation radius (m) = 100; Aquifer transmissivity (m²/day) = 250; Confined storativity = 0.0005; Observation time (days) = 4. Net pumping drawdown: 0.324632 m Time parameter since history origin: 0.00125 Pumping starts at 500 m³/day, rises to 800 on day 1 and stops on day 3. At a 100 m observation radius the day-4 result includes both drawdown history and one day of recovery.