How to use this calculator
Resolve separate temperatures when two internally uniform components exchange heat with each other and the environment.
- Enter Node 1 heat capacity (J/K), Node 2 heat capacity (J/K), Inter-node conductance (W/K), Node 1 to ambient conductance (W/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Coupled two body transient thermal network explained
A numerical walkthrough
Node 1 heat capacity (J/K) = 1000; Node 2 heat capacity (J/K) = 2000; Inter-node conductance (W/K) = 5; Node 1 to ambient conductance (W/K) = 1; Node 2 to ambient conductance (W/K) = 2; Node 1 initial temperature (°C) = 100; Node 2 initial temperature (°C) = 20; Fixed ambient temperature (°C) = 20; Elapsed time (s) = 300.
- Node 1 temperature: 43.919508 °C
- Node 2 temperature: 37.672975 °C
- Inter-node heat flow: 31.232666 W
A 1,000 J/K component at 100 °C contacts a 2,000 J/K component at 20 °C through 5 W/K, with separate ambient losses. After 300 s the nodes are 43.9195 and 37.6730 °C, still exchanging 31.2327 W; one combined body would hide this lag.
The model behind the numbers
C₁dT₁/dt=−G(T₁−T₂)−G₁(T₁−Ta); C₂dT₂/dt=G(T₁−T₂)−G₂(T₂−Ta); θ(t)=exp(At)θ(0).
Solve the coupled linear energy balances using an exact 2-by-2 matrix exponential. This preserves thermal interaction that cannot be represented by assigning one body a single combined heat capacity.
What to enter
C1— Node 1 heat capacity (J/K)- Node 1 heat capacity (J/K). Enter the value for this state; the units shown are used without an unstated conversion.
C2— Node 2 heat capacity (J/K)- Node 2 heat capacity (J/K). Enter the value for this state; the units shown are used without an unstated conversion.
G— Inter-node conductance (W/K)- Inter-node conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
G1— Node 1 to ambient conductance (W/K)- Node 1 to ambient conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
G2— Node 2 to ambient conductance (W/K)- Node 2 to ambient conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
T1— Node 1 initial temperature (°C)- Node 1 initial temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
T2— Node 2 initial temperature (°C)- Node 2 initial temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
Ta— Fixed ambient temperature (°C)- Fixed ambient temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
t— Elapsed time (s)- Elapsed time (s). Enter the value for this state; the units shown are used without an unstated conversion.
Interpreting the result
Each node is internally lumped, conductances and heat capacities constant, no sources or radiation nonlinearity. Verify small internal gradients within each component.
Reading the outputs
Returns both temperatures and signed instantaneous heat flow from node 1 to node 2.
Frequently asked questions
Can the two nodes be insulated from ambient?
Yes. Set both ambient conductances to zero; their total energy is then conserved.
Can the bodies be thermally disconnected?
Yes. Zero inter-node conductance lets them cool independently.
Why does one body initially heat while the other cools?
The hotter component transfers stored energy to the colder one before ambient losses dominate.
How do I use the Coupled two body transient thermal network calculator?
Enter Node 1 heat capacity (J/K), Node 2 heat capacity (J/K), Inter-node conductance (W/K), Node 1 to ambient conductance (W/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Coupled two body transient thermal network?
Node 1 heat capacity (J/K) = 1000; Node 2 heat capacity (J/K) = 2000; Inter-node conductance (W/K) = 5; Node 1 to ambient conductance (W/K) = 1; Node 2 to ambient conductance (W/K) = 2; Node 1 initial temperature (°C) = 100; Node 2 initial temperature (°C) = 20; Fixed ambient temperature (°C) = 20; Elapsed time (s) = 300. Node 1 temperature: 43.919508 °C Node 2 temperature: 37.672975 °C Inter-node heat flow: 31.232666 W A 1,000 J/K component at 100 °C contacts a 2,000 J/K component at 20 °C through 5 W/K, with separate ambient losses. After 300 s the nodes are 43.9195 and 37.6730 °C, still exchanging 31.2327 W; one combined body would hide this lag.
Read our calculation methodology.