How to use this calculator
Compare trial dynamic-compaction layouts through an explicitly calibrated influence-depth estimate and nominal surface energy intensity.
- Enter Tamper mass (tonnes), Drop height (m), Empirical influence coefficient, Drops per point, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Dynamic compaction influence depth and energy density explained
The depth relation is an empirical fit using tamper mass, drop height and a site-calibrated coefficient; it is not a universal soil-depth prediction. The energy-density calculation separately divides drop potential energy by the square spacing between impact points.
Inputs, symbols, and units
M— Tamper mass (tonnes)- Falling tamper mass in metric tonnes.
H— Drop height (m)- Nominal vertical free-fall height.
alpha— Empirical influence coefficient- Site-calibrated coefficient for D=α√(Mtonne Hm); units and calibration are specific to this empirical relation.
n— Drops per point- Number of drops at each impact point. Enter a whole number.
s— Square-grid spacing (m)- Plan spacing between impact points on an ideal square grid.
Formula and method
D=α√(Mtonne Hm); Edrop=MgH in kJ for M in tonnes; Earea=nEdrop/s² for square spacing s.
The depth coefficient is empirical and unit-dependent. Potential energy is a nominal delivered upper budget, not a measured fraction reaching the target soil layer.
A worked scenario
Tamper mass (tonnes) = 15; Drop height (m) = 20; Empirical influence coefficient = 0.5; Drops per point = 10; Square-grid spacing (m) = 5.
- Empirical influence depth: 8.660254 m
- Nominal energy per unit area: 1176.798 kJ/m²
- Potential energy per drop: 2941.995 kJ
A 15 tonne tamper dropped 20 m with α=0.5 gives an empirical 8.66 m influence depth. Ten drops on a 5 m grid supply about 1176.8 kJ/m² nominal energy.
Assumptions and edge cases
Empirical trial planning only. Saturation, fines, drainage, vibration-sensitive surroundings, crater backfill, energy losses and actual densification require field trials and monitoring. Educational model; this is not a code-compliant design check.
Reading the outputs
Influence depth is m, energy density is kJ/m² and potential energy per drop is kJ.
Frequently asked questions
Can alpha be copied from another soil?
It should be justified or calibrated for the site and the exact unit convention; it is not universal.
Does twice the energy guarantee twice the depth?
No. This empirical depth varies with the square root of mass-height product and does not model densification directly.
Does the area energy include repeated passes?
Enter the total drops represented per point, or calculate each pass consistently before summing energy.
How do I use the Dynamic compaction influence depth and energy density calculator?
Enter Tamper mass (tonnes), Drop height (m), Empirical influence coefficient, Drops per point, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Dynamic compaction influence depth and energy density?
Tamper mass (tonnes) = 15; Drop height (m) = 20; Empirical influence coefficient = 0.5; Drops per point = 10; Square-grid spacing (m) = 5. Empirical influence depth: 8.660254 m Nominal energy per unit area: 1176.798 kJ/m² Potential energy per drop: 2941.995 kJ A 15 tonne tamper dropped 20 m with α=0.5 gives an empirical 8.66 m influence depth. Ten drops on a 5 m grid supply about 1176.8 kJ/m² nominal energy.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume I.
Read our calculation methodology.