CalcWorldHub
Free online calculator · no signup

Fin array source temperature with base contact calculator

Check an electronics heat-sink array’s source temperature while accounting for covered base area and source-to-base contact resistance.

4,000 tools
Fin array source temperature with base contact calculator — Base plate width across fins (m), Fin and base depth (m), Fin thickness (m) and calculation method
Fin array source temperature with base contact calculator: inputs and calculation method.

How to use this calculator

Check an electronics heat-sink array’s source temperature while accounting for covered base area and source-to-base contact resistance.

  1. Enter Base plate width across fins (m), Fin and base depth (m), Fin thickness (m), Fin height above base (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Fin array source temperature with base contact explained

Source temperature51.0354°C
Source temperature: 51.035394 °C in the worked scenario.

A numerical walkthrough

Base plate width across fins (m) = 0.1; Fin and base depth (m) = 0.08; Fin thickness (m) = 0.002; Fin height above base (m) = 0.03; Number of parallel fins = 12; Fin conductivity (W/m/K) = 200; Effective array convection coefficient (W/m²/K) = 20; Applied source heat (W) = 30; Source-to-base contact resistance (K/W) = 0.1; Ambient temperature (°C) = 25.

  • Source temperature: 51.035394 °C
  • Base plate temperature: 48.035394 °C
  • Source to ambient thermal resistance: 0.867846 K/W
  • Individual fin efficiency: 0.968458

A 30 W source sits behind a 0.1 K/W contact resistance and a 12-fin aluminum array in 25 °C air. The base reaches 48.0354 °C and the source 51.0354 °C; the 3 K contact rise remains even when the fins perform well.

The model behind the numbers

Aexposed=Ww−Nw th; G=h(Aexposed+NηP Lc); Tbase=Ta+Q/G; Tsource=Tbase+Q Rc.

Combine all fin conductances and the remaining exposed base in parallel, then add the shared contact resistance in series. Use an effective convection coefficient that already reflects fin spacing and airflow.

What to enter

W — Base plate width across fins (m)
Base plate width across fins (m). Enter the value for this state; the units shown are used without an unstated conversion.
w — Fin and base depth (m)
Fin and base depth (m). Enter the value for this state; the units shown are used without an unstated conversion.
th — Fin thickness (m)
Fin thickness (m). Enter the value for this state; the units shown are used without an unstated conversion.
L — Fin height above base (m)
Fin height above base (m). Enter the value for this state; the units shown are used without an unstated conversion.
N — Number of parallel fins
Number of parallel fins. Enter the value for this state; the units shown are used without an unstated conversion.
k — Fin conductivity (W/m/K)
Fin conductivity (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
hc — Effective array convection coefficient (W/m²/K)
Effective array convection coefficient (W/m²/K). Enter the value for this state; the units shown are used without an unstated conversion.
Q — Applied source heat (W)
Applied source heat (W). Enter the value for this state; the units shown are used without an unstated conversion.
Rc — Source-to-base contact resistance (K/W)
Source-to-base contact resistance (K/W). Enter the value for this state; the units shown are used without an unstated conversion.
Ta — Ambient temperature (°C)
Ambient temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.

Interpreting the result

Isothermal base, identical thin rectangular fins, corrected-tip approximation and a supplied effective array convection coefficient. It does not predict airflow restriction or optimize spacing.

Reading the outputs

Returns source and base temperatures, total source-to-ambient thermal resistance and each fin’s efficiency.

Frequently asked questions

Does adding fins always help in practice?

Not necessarily. More fins can reduce airflow; update the supplied effective h for the actual array.

Why subtract fin footprints from the base?

Those strips are covered by fins and do not convect directly to ambient.

Is contact resistance divided by the number of fins?

No. The entered source-to-base resistance is shared in series with the entire array.

How do I use the Fin array source temperature with base contact calculator?

Enter Base plate width across fins (m), Fin and base depth (m), Fin thickness (m), Fin height above base (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Fin array source temperature with base contact?

Base plate width across fins (m) = 0.1; Fin and base depth (m) = 0.08; Fin thickness (m) = 0.002; Fin height above base (m) = 0.03; Number of parallel fins = 12; Fin conductivity (W/m/K) = 200; Effective array convection coefficient (W/m²/K) = 20; Applied source heat (W) = 30; Source-to-base contact resistance (K/W) = 0.1; Ambient temperature (°C) = 25. Source temperature: 51.035394 °C Base plate temperature: 48.035394 °C Source to ambient thermal resistance: 0.867846 K/W Individual fin efficiency: 0.968458 A 30 W source sits behind a 0.1 K/W contact resistance and a 12-fin aluminum array in 25 °C air.