CalcWorldHub
Free online calculator · no signup

Glover Balmer stream depletion rate and volume calculator

Estimate the time-dependent streamflow reduction caused by a nearby pumping well, including cumulative intercepted stream water.

4,000 tools
Glover Balmer stream depletion rate and volume calculator — Constant groundwater pumping rate (m³/day), Well to stream distance (m), Aquifer transmissivity (m²/day) and calculation method
Glover Balmer stream depletion rate and volume calculator: inputs and calculation method.

How to use this calculator

Estimate the time-dependent streamflow reduction caused by a nearby pumping well, including cumulative intercepted stream water.

  1. Enter Constant groundwater pumping rate (m³/day), Well to stream distance (m), Aquifer transmissivity (m²/day), Aquifer storage coefficient, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Glover Balmer stream depletion rate and volume explained

For steady pumping beside an ideal fully penetrating stream, the depletion fraction follows a complementary-error-function response governed by distance, transmissivity, storage, and time. Cumulative depletion uses the integrated response, not the final rate multiplied by the full duration.

Current stream depletion369.4413m³/day
Current stream depletion: 369.44134 m³/day in the worked scenario.

Inputs, symbols, and units

Q — Constant groundwater pumping rate (m³/day)
Extraction from a well beside the ideal stream.
a — Well to stream distance (m)
Perpendicular separation from the fully penetrating stream boundary.
T — Aquifer transmissivity (m²/day)
Horizontal conductivity times saturated aquifer thickness.
S — Aquifer storage coefficient
Storage coefficient appropriate to the ideal analytical response.
t — Elapsed pumping time (days)
Duration of uninterrupted extraction.

Formula and method

qstream/Q=erfc[a√(S/(4Tt))]; V=Q[(t+a²S/(2T))erfc(z)−a√(St/(πT))e^(−z²)].

The stream is an ideal fully penetrating, constant-head boundary with no bed resistance. The cumulative value integrates depletion from pumping start; it is not current depletion multiplied by time.

A worked scenario

Constant groundwater pumping rate (m³/day) = 500; Well to stream distance (m) = 200; Aquifer transmissivity (m²/day) = 300; Aquifer storage coefficient = 0.05; Elapsed pumping time (days) = 30.

  • Current stream depletion: 369.44134 m³/day
  • Current depletion fraction: 73.888268 %
  • Cumulative stream depletion: 8540.879062 m³

A well 200 m from the ideal stream pumps 500 m³/day for 30 days through T=300 m²/day and storage coefficient 0.05.

Assumptions and edge cases

Ideal Glover–Balmer assumptions; partial penetration and streambed resistance can markedly change depletion. No allocation, ecological impact or permit determination is made. Educational model; this is not a code-compliant design check.

Reading the outputs

Current depletion is m³/day, its fraction of pumping is percent and cumulative depletion is m³.

Frequently asked questions

Does depletion equal pumping immediately?

No. Storage initially supplies much of the extraction; stream capture grows with the diffusion response.

Why not multiply current depletion by duration?

That would apply the final rate to earlier times and overstate the cumulative volume.

Can a small shallow stream use this model directly?

Its fully penetrating, resistance-free boundary may be inappropriate; a finite streambed conductance model can be necessary.

How do I use the Glover Balmer stream depletion rate and volume calculator?

Enter Constant groundwater pumping rate (m³/day), Well to stream distance (m), Aquifer transmissivity (m²/day), Aquifer storage coefficient, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Glover Balmer stream depletion rate and volume?

Constant groundwater pumping rate (m³/day) = 500; Well to stream distance (m) = 200; Aquifer transmissivity (m²/day) = 300; Aquifer storage coefficient = 0.05; Elapsed pumping time (days) = 30. Current stream depletion: 369.44134 m³/day Current depletion fraction: 73.888268 % Cumulative stream depletion: 8540.879062 m³ A well 200 m from the ideal stream pumps 500 m³/day for 30 days through T=300 m²/day and storage coefficient 0.05.