How to use this calculator
Estimate the time-dependent streamflow reduction caused by a nearby pumping well, including cumulative intercepted stream water.
- Enter Constant groundwater pumping rate (m³/day), Well to stream distance (m), Aquifer transmissivity (m²/day), Aquifer storage coefficient, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Glover Balmer stream depletion rate and volume explained
For steady pumping beside an ideal fully penetrating stream, the depletion fraction follows a complementary-error-function response governed by distance, transmissivity, storage, and time. Cumulative depletion uses the integrated response, not the final rate multiplied by the full duration.
Inputs, symbols, and units
Q— Constant groundwater pumping rate (m³/day)- Extraction from a well beside the ideal stream.
a— Well to stream distance (m)- Perpendicular separation from the fully penetrating stream boundary.
T— Aquifer transmissivity (m²/day)- Horizontal conductivity times saturated aquifer thickness.
S— Aquifer storage coefficient- Storage coefficient appropriate to the ideal analytical response.
t— Elapsed pumping time (days)- Duration of uninterrupted extraction.
Formula and method
qstream/Q=erfc[a√(S/(4Tt))]; V=Q[(t+a²S/(2T))erfc(z)−a√(St/(πT))e^(−z²)].
The stream is an ideal fully penetrating, constant-head boundary with no bed resistance. The cumulative value integrates depletion from pumping start; it is not current depletion multiplied by time.
A worked scenario
Constant groundwater pumping rate (m³/day) = 500; Well to stream distance (m) = 200; Aquifer transmissivity (m²/day) = 300; Aquifer storage coefficient = 0.05; Elapsed pumping time (days) = 30.
- Current stream depletion: 369.44134 m³/day
- Current depletion fraction: 73.888268 %
- Cumulative stream depletion: 8540.879062 m³
A well 200 m from the ideal stream pumps 500 m³/day for 30 days through T=300 m²/day and storage coefficient 0.05.
Assumptions and edge cases
Ideal Glover–Balmer assumptions; partial penetration and streambed resistance can markedly change depletion. No allocation, ecological impact or permit determination is made. Educational model; this is not a code-compliant design check.
Reading the outputs
Current depletion is m³/day, its fraction of pumping is percent and cumulative depletion is m³.
Frequently asked questions
Does depletion equal pumping immediately?
No. Storage initially supplies much of the extraction; stream capture grows with the diffusion response.
Why not multiply current depletion by duration?
That would apply the final rate to earlier times and overstate the cumulative volume.
Can a small shallow stream use this model directly?
Its fully penetrating, resistance-free boundary may be inappropriate; a finite streambed conductance model can be necessary.
How do I use the Glover Balmer stream depletion rate and volume calculator?
Enter Constant groundwater pumping rate (m³/day), Well to stream distance (m), Aquifer transmissivity (m²/day), Aquifer storage coefficient, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Glover Balmer stream depletion rate and volume?
Constant groundwater pumping rate (m³/day) = 500; Well to stream distance (m) = 200; Aquifer transmissivity (m²/day) = 300; Aquifer storage coefficient = 0.05; Elapsed pumping time (days) = 30. Current stream depletion: 369.44134 m³/day Current depletion fraction: 73.888268 % Cumulative stream depletion: 8540.879062 m³ A well 200 m from the ideal stream pumps 500 m³/day for 30 days through T=300 m²/day and storage coefficient 0.05.
Background or definition reference: USGS STRMDEPL08 analytical stream-depletion models.
Read our calculation methodology.