CalcWorldHub
Free online calculator · no signup

Pumping drawdown beside a straight aquifer boundary calculator

Apply one image well to represent a straight impermeable or maintained-head aquifer edge and separate its effect from the real pumping well.

4,000 tools
Pumping drawdown beside a straight aquifer boundary calculator — Pumping rate (m³/day), Transmissivity (m²/day), Storativity and calculation method
Pumping drawdown beside a straight aquifer boundary calculator: inputs and calculation method.

How to use this calculator

Apply one image well to represent a straight impermeable or maintained-head aquifer edge and separate its effect from the real pumping well.

  1. Enter Pumping rate (m³/day), Transmissivity (m²/day), Storativity, Well distance from boundary (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Pumping drawdown beside a straight aquifer boundary explained

Enter pumping rate, transmissivity, storativity, and observation coordinates to compare the real well with its signed image across the chosen straight boundary.

Boundary-adjusted drawdown1.4336m
Boundary-adjusted drawdown: 1.433571 m in the worked scenario.

A numerical walkthrough

Pumping rate (m³/day) = 400; Transmissivity (m²/day) = 200; Storativity = 0.001; Well distance from boundary (m) = 80; Observation x coordinate (m) = 100; Observation along-boundary coordinate (m) = 50; Elapsed pumping time (days) = 2; Boundary condition = barrier.

  • Boundary-adjusted drawdown: 1.433571 m
  • Real-well contribution: 0.913174 m
  • Image-well contribution: 0.520397 m

An extraction well lies 80 m from a straight boundary. A point at (100,50) m is observed after two days; the barrier image adds drawdown while a fixed-head image subtracts it.

The model behind the numbers

s=sTheis(rreal)+εsTheis(rimage), where ε=+1 for no flow and −1 for fixed head; image well is at (−a,0).

The aquifer occupies x≥0. Choose the physical boundary condition rather than adjusting the image sign to force a desired answer.

What to enter

Q — Pumping rate (m³/day)
Constant extraction at coordinates (a,0).
T — Transmissivity (m²/day)
Uniform aquifer transmissivity on the x≥0 side.
S — Storativity
Uniform confined storage coefficient.
a — Well distance from boundary (m)
Real well x coordinate; the straight boundary is x=0.
x — Observation x coordinate (m)
Distance into the aquifer from the boundary.
y — Observation along-boundary coordinate (m)
Signed coordinate parallel to the boundary, with the real well at y=0.
t — Elapsed pumping time (days)
Time since extraction began.
mode — Boundary condition
Barrier uses an equal extraction image; fixed head uses an equal recharge image. Choose barrier, head.

Interpreting the result

This solution assumes one infinite straight boundary, a homogeneous confined aquifer, and fully penetrating wells. Two boundaries, finite streams, leaky beds, or finite aquifer extent need another solution; use a site-specific hydrogeologic analysis for design.

Reading the outputs

All three values are m of drawdown; an image contribution can be negative because it represents mathematical recharge.

Frequently asked questions

What should fixed-head drawdown be directly at the boundary?

Zero, because real and recharge-image distances match there.

Does a no-flow barrier mean no drawdown?

No. It blocks recharge from across the boundary and the same-sign image increases drawdown.

Can x be negative?

No. The modeled physical aquifer is the nonnegative-x half-plane.

How do I use the Pumping drawdown beside a straight aquifer boundary calculator?

Enter Pumping rate (m³/day), Transmissivity (m²/day), Storativity, Well distance from boundary (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Pumping drawdown beside a straight aquifer boundary?

Pumping rate (m³/day) = 400; Transmissivity (m²/day) = 200; Storativity = 0.001; Well distance from boundary (m) = 80; Observation x coordinate (m) = 100; Observation along-boundary coordinate (m) = 50; Elapsed pumping time (days) = 2; Boundary condition = barrier. Boundary-adjusted drawdown: 1.433571 m Real-well contribution: 0.913174 m Image-well contribution: 0.520397 m An extraction well lies 80 m from a straight boundary. A point at (100,50) m is observed after two days; the barrier image adds drawdown while a fixed-head image subtracts it.