How to use this calculator
Move a symmetric FIR impulse response toward the earliest possible energy arrival while approximately retaining its magnitude response.
- Enter Odd symmetric FIR coefficients. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Homomorphic minimum phase FIR conversion explained
Homomorphic conversion derives a causal minimum-phase FIR sequence from the supplied finite impulse response; the output is a new coefficient set, not a phase-preserving copy.
How the calculation works
c=IDFT(log|DFT(h)|); retain c0, double positive quefrencies and retain the Nyquist cepstrum; hmin≈IDFT(exp(DFT(cmin))). Use FFT length 256 and keep original tap count.
A fixed 256-point homomorphic construction forms a causal cepstrum. Keeping the original number of taps makes the result a finite numerical approximation, not an exact root-reflection factorization.
Set up the calculation
kernel— Odd symmetric FIR coefficients- Real odd-length symmetric filter with no zero magnitude on the 256-point inspection grid. Use comma-separated values in the stated order.
Limits of this model
Spectral zeros on the inspection grid are rejected; finite FFT size and truncation cause magnitude error. No guarantee is made for zeros between inspection bins.
Check this example
Odd symmetric FIR coefficients = [0.2, 0.5, 0.2].
- Converted leading coefficient: 0.4 ratio
- Converted coefficient sum: 0.9 ratio
- Minimum-phase approximation tap 0: 0.4 ratio
- Minimum-phase approximation tap 1: 0.4 ratio
- Minimum-phase approximation tap 2: 0.1 ratio
The symmetric three-tap kernel [0.2,0.5,0.2] is converted into an earlier-energy response with similar magnitude and a different phase.
Reading the outputs
Every converted coefficient is listed; their sum is the approximate DC gain after truncation.
Frequently asked questions
Does minimum phase mean zero phase?
No. It changes phase to place energy earlier while retaining magnitude approximately.
Why are exact spectral zeros rejected?
Their logarithms are singular in this construction.
Can the new coefficients be used in a causal filter?
Yes. They are returned in increasing delay order.
How do I use the Homomorphic minimum phase FIR conversion calculator?
Enter Odd symmetric FIR coefficients. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Homomorphic minimum phase FIR conversion?
Odd symmetric FIR coefficients = [0.2, 0.5, 0.2]. Converted leading coefficient: 0.4 ratio Converted coefficient sum: 0.9 ratio Minimum-phase approximation tap 0: 0.4 ratio Minimum-phase approximation tap 1: 0.4 ratio Minimum-phase approximation tap 2: 0.1 ratio The symmetric three-tap kernel [0.2,0.5,0.2] is converted into an earlier-energy response with similar magnitude and a different phase.
Background or definition reference: SciPy homomorphic minimum-phase method.