PV Module Power Temperature Derating Calculator: inputs and calculation method.

How to use this calculator

Estimate photovoltaic module power at cell temperature from its STC rating and power temperature coefficient.

  1. Enter Rated maximum power at STC (W), Power temperature coefficient (%/°C), Cell temperature (°C). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Energy calculation

How this calculation works

A module’s maximum power changes approximately linearly with cell temperature near its rated operating point. This estimate applies the manufacturer power coefficient relative to the 25 °C standard test temperature.

Inputs and units

stcPowerW — Rated maximum power at STC (W)
Module maximum power rating at 1,000 W/m² and 25 °C cell temperature.
gammaPctPerC — Power temperature coefficient (%/°C)
Use the signed manufacturer value, commonly negative for crystalline-silicon modules.
cellTempC — Cell temperature (°C)
Estimated PV cell temperature, not ambient air temperature.

Formula

Displayed formula

P(T) = P_STC × [1 + (γ / 100) × (T_cell − 25 °C)], where γ is in %/°C.

Method

Enter the module’s STC power, its power temperature coefficient, and estimated cell temperature. The result isolates temperature adjustment at STC irradiance.

Worked example

A 400 W module with γ = −0.35%/°C at a 55 °C cell temperature has ΔT = 30 °C and estimated power 400 × (1 − 0.0035 × 30) = 358 W.

Assumptions and limits

Assumes a linear temperature coefficient and holds irradiance, spectrum, and other module conditions at the STC reference. It does not estimate cell temperature or full array performance; use manufacturer data and an appropriate system model.

Frequently asked questions

What temperature should I enter?

Use cell temperature; it can be higher than outdoor air temperature in sunlight.

What does STC mean?

Standard Test Conditions use 1,000 W/m² irradiance and a 25 °C cell temperature.

Does this predict complete array output?

No. It adjusts rated module power for temperature only and holds other conditions fixed.

How do I use the PV Module Power Temperature Derating Calculator?

Enter Rated maximum power at STC (W), Power temperature coefficient (%/°C), Cell temperature (°C). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of PV Module Power Temperature Derating?

A 400 W module with γ = −0.35%/°C at a 55 °C cell temperature has ΔT = 30 °C and estimated power 400 × (1 − 0.0035 × 30) = 358 W.