How to use this calculator
Calculate photovoltaic fill factor from maximum-power voltage and current and open-circuit voltage and short-circuit current.
- Enter Maximum-power voltage Vmp (V), Maximum-power current Imp (A), Open-circuit voltage Voc (V), Short-circuit current Isc (A). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Photovoltaic fill factor describes how much of the open-circuit-voltage by short-circuit-current rectangle is realized at the maximum-power point of an I–V curve. It is a dimensionless cell or module quality metric. The voltage and current values must come from the same device curve and test condition.
Inputs and units
vmp— Maximum-power voltage Vmp (V)- Enter voltage at the maximum-power point.
imp— Maximum-power current Imp (A)- Enter current at the maximum-power point.
voc— Open-circuit voltage Voc (V)- Use the open-circuit voltage from the same I–V curve.
isc— Short-circuit current Isc (A)- Use the short-circuit current from the same I–V curve.
Formula
FF = (V_mp I_mp)/(V_oc I_sc) × 100%.
Method
Multiply the maximum-power voltage V_mp by its current I_mp, then divide by the product of open-circuit voltage V_oc and short-circuit current I_sc. Multiply by 100 for percent.
Worked example
For Vmp = 0.52 V, Imp = 1.15 A, Voc = 0.62 V, and Isc = 1.25 A, Pmax = 0.5980 W and fill factor = 77.16%.
Assumptions and limits
Use values measured on the same I–V curve under the same irradiance and temperature. Fill factor is not module conversion efficiency; efficiency also requires incident irradiance and active area.
Frequently asked questions
What does fill factor measure?
It compares the measured maximum-power point with the Voc × Isc rectangle on the same current–voltage curve.
Is fill factor the same as solar-cell efficiency?
No. Efficiency also compares maximum electrical power with incident optical power over the cell area.
Can Vmp exceed Voc or Imp exceed Isc?
No. For a conventional photovoltaic I–V curve, the maximum-power point lies within those voltage and current bounds.
How do I use the Solar Cell Fill Factor Calculator?
Enter Maximum-power voltage Vmp (V), Maximum-power current Imp (A), Open-circuit voltage Voc (V), Short-circuit current Isc (A). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Solar Cell Fill Factor?
For Vmp = 0.52 V, Imp = 1.15 A, Voc = 0.62 V, and Isc = 1.25 A, Pmax = 0.5980 W and fill factor = 77.16%.
Reference: National Renewable Energy Laboratory solar-cell current-voltage relation and fill factor. See our calculation methodology.