How to use this calculator
Estimate the time to heat a tank volume from inlet temperature to a target using heater power and efficiency.
- Enter Tank water volume (L), Starting water temperature (°C), Target water temperature (°C), Heater input power (kW), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Recovery time is the energy required to raise the stored water temperature divided by useful heater output. It helps compare expected recovery with appliance specifications under a steady no-draw condition.
Inputs and units
volume— Tank water volume (L)- Water volume being heated.
inlet— Starting water temperature (°C)- Initial bulk water temperature.
target— Target water temperature (°C)- Desired final bulk water temperature.
power— Heater input power (kW)- Rated energy input while heating.
eff— Heating efficiency (%)- Fraction of input delivered to water.
Formula
t (h) = V × ρ × cₚ × ΔT ÷ (3,600,000 × P × η), using water ρ≈1 kg/L and cₚ≈4,186 J/(kg·°C).
Worked example
Heating 190 L of water from 12°C to 55°C requires about 9.50 kWh delivered. At 4.5 kW input and 95% efficiency, idealized recovery is about 2.22 hours.
Assumptions and limits
Approximate water properties and constant heater power. Excludes tank standby losses, stratification, burner cycling, incoming flow during recovery, and draws during heating.
Frequently asked questions
Why does actual recovery take longer?
Standby losses, burner modulation, tank mixing, and simultaneous draws can extend real recovery time.
Should I use input or output heater power?
Enter rated input power and efficiency; the calculator applies efficiency once.
Does it include water use while heating?
No. It models a closed tank volume with no draw during recovery.
How do I use the Water heater recovery time calculator?
Enter Tank water volume (L), Starting water temperature (°C), Target water temperature (°C), Heater input power (kW), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Water heater recovery time?
Heating 190 L of water from 12°C to 55°C requires about 9.50 kWh delivered. At 4.5 kW input and 95% efficiency, idealized recovery is about 2.22 hours.
Read our calculation methodology.