How to use this calculator
Find the storage excursion required by paired inflow and prescribed release hydrographs, including any starting water needed to sustain the release plan.
- Enter Inflow ordinates (m³/s), Specified outflow ordinates (m³/s), Hydrograph time step (s). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Detention storage from cumulative inflow outflow hydrographs explained
How the calculation works
Vk=Σ[(Ij−1+Ij−Oj−1−Oj)Δt/2]; active range=max(V)−min(V); required initial storage=−min(0,V).
Linearly interpolated inflow and outflow create quadratic cumulative volume within each interval; zero crossings of net inflow are checked for interior extrema. Cumulative volumes are formed relative to an arbitrary zero initial state. Shifting by the most negative cumulative value supplies the least initial fill that avoids a negative storage volume.
Set up the calculation
I— Inflow ordinates (m³/s)- Sampled inflow at uniform time spacing. Use comma-separated values in the stated order.
O— Specified outflow ordinates (m³/s)- Specified release plan on the same time grid; it is not an outlet rating solved by the calculator. Use comma-separated values in the stated order.
dt— Hydrograph time step (s)- Uniform interval used for trapezoidal volume integration.
Limits of this model
A specified feasible release hydrograph is assumed. The calculator does not verify that an actual outlet can deliver it at the available stage or under downstream constraints. Educational model; this is not a code-compliant design check.
Check this example
Inflow ordinates (m³/s) = [0, 5, 12, 8, 2, 0, 0]; Specified outflow ordinates (m³/s) = [0, 1, 3, 4, 4, 3, 2]; Hydrograph time step (s) = 600.
- Minimum active storage range: 9800 m³
- Initial storage needed for release plan: 0 m³
- Final storage with that initial fill: 6600 m³
- Time of maximum cumulative storage: 2200 s
Ten-minute inflow samples rise to 12 m³/s while releases peak at 4 m³/s. The mass curve identifies peak stored volume rather than comparing only the two discharge peaks.
Reading the outputs
Storage range, initial fill and final shifted storage are m³; peak time is a second offset, including interior extrema between sample times.
Source
USACE HEC-HMS Technical Reference Manual, Reservoir Modeling. Covers storage response to inflow and outflow hydrographs; this calculator assumes both traces are supplied.
Frequently asked questions
Why might initial storage be positive?
The release plan can demand water before cumulative inflow supplies it.
Is active storage equal to total reservoir volume?
No. Dead storage, freeboard, sediment allowance and operational constraints are additional.
Does matching event peak inflow and outflow eliminate storage?
No. Their timing and cumulative volumes determine storage demand.
How do I use the Detention storage from cumulative inflow outflow hydrographs calculator?
Enter Inflow ordinates (m³/s), Specified outflow ordinates (m³/s), Hydrograph time step (s). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Detention storage from cumulative inflow outflow hydrographs?
Inflow ordinates (m³/s) = [0, 5, 12, 8, 2, 0, 0]; Specified outflow ordinates (m³/s) = [0, 1, 3, 4, 4, 3, 2]; Hydrograph time step (s) = 600. Minimum active storage range: 9800 m³ Initial storage needed for release plan: 0 m³ Final storage with that initial fill: 6600 m³ Time of maximum cumulative storage: 2200 s Ten-minute inflow samples rise to 12 m³/s while releases peak at 4 m³/s. The mass curve identifies peak stored volume rather than comparing only the two discharge peaks.
Read our calculation methodology.