Hot and Cold Water Mixing Ratio Calculator

Find the hot- and cold-water volumes needed to reach a target mixed temperature.

4,000 tools
Hot and Cold Water Mixing Ratio Calculator — Hot-water temperature (°C), Cold-water temperature (°C), Target mixed temperature (°C) and calculation method
Hot and Cold Water Mixing Ratio Calculator: inputs and calculation method.

How to use this calculator

Find the hot- and cold-water volumes needed to reach a target mixed temperature.

  1. Enter Hot-water temperature (°C), Cold-water temperature (°C), Target mixed temperature (°C), Total mixed-water volume (L). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Home & construction calculation

How this calculation works

A simple mixing balance estimates the hot and cold portions of a water batch when both streams have similar density and heat capacity. The result gives the blend proportions and the volumes required for a selected total batch.

Inputs and units

hotTempC — Hot-water temperature (°C)
Temperature of the hot stream before mixing.
coldTempC — Cold-water temperature (°C)
Temperature of the cold stream before mixing.
targetTempC — Target mixed temperature (°C)
Desired final temperature between the hot and cold stream temperatures.
totalVolumeL — Total mixed-water volume (L)
Combined hot- and cold-water volume after mixing.

Formula

Displayed formula

Hot fraction = (target temperature − cold temperature) ÷ (hot temperature − cold temperature); hot volume = total volume × hot fraction.

Method

Enter hot and cold stream temperatures, a target between them, and the desired mixed-water volume. Temperature differences may be entered in Celsius because the ratio uses differences.

Worked example

Mixing 60°C hot water with 15°C cold water to make 100 L at 40°C requires about 55.56 L hot water and 44.44 L cold water.

Assumptions and limits

Assumes water streams with equal specific heat, negligible heat loss, and complete mixing. Pipe losses, tank stratification, changing source temperature, and non-water fluids can change the delivered temperature.

Frequently asked questions

How is the mix ratio calculated?

The temperature rise above the cold stream determines the hot-water fraction of the total blend.

Can the target be outside the two source temperatures?

The target must be between the hot and cold inputs for a two-stream mixture.

Does the result account for heat lost in pipes?

No. It is an ideal mixing estimate; measure the delivered water temperature when system losses matter.

How do I use the Hot and Cold Water Mixing Ratio Calculator?

Enter Hot-water temperature (°C), Cold-water temperature (°C), Target mixed temperature (°C), Total mixed-water volume (L). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Hot and Cold Water Mixing Ratio?

Mixing 60°C hot water with 15°C cold water to make 100 L at 40°C requires about 55.56 L hot water and 44.44 L cold water.