How to use this calculator
Estimate received optical power, sensitivity margin, and loss-limited reach for a passive fiber link.
- Enter Transmitter launch power (dBm), Receiver sensitivity (dBm), Installed fiber length (km), Fiber attenuation (dB/km), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
A first-pass fiber link budget adds attenuation along the fiber to connector and splice losses, then compares received power with the receiver sensitivity. The remaining power margin can be reserved for the maximum fiber length under the entered assumptions.
Inputs and units
txPowerDbm— Transmitter launch power (dBm)- Mean launch power at the transmitter reference point.
receiverSensitivityDbm— Receiver sensitivity (dBm)- Minimum received power required by the receiver specification.
linkLengthKm— Installed fiber length (km)- Fiber route length included in the current link.
fiberAttenuationDbKm— Fiber attenuation (dB/km)- Attenuation coefficient at the operating wavelength.
connectorCount— Connector pairs or connections (count)- Number of connection losses represented in the path.
connectorLossDb— Loss per connector (dB)- Insertion loss assigned to each counted connector.
spliceCount— Splices (count)- Number of fusion or mechanical splice losses represented in the path.
spliceLossDb— Loss per splice (dB)- Insertion loss assigned to each counted splice.
designMarginDb— Reserved design margin (dB)- Power margin reserved after passive losses.
Formula
P_rx = P_tx − [αL + N_c L_c + N_s L_s]; margin = P_rx − sensitivity; L_max = (P_tx − sensitivity − reserve − N_c L_c − N_s L_s)/α.
Method
Enter launch power and receiver sensitivity in dBm, fiber attenuation in dB/km, link length, connector and splice counts and losses, and a desired reserve margin. The calculation sums passive losses in dB before comparing endpoint powers.
Worked example
For 0 dBm launch power, −28 dBm receiver sensitivity, 20 km at 0.35 dB/km, two 0.5 dB connectors, ten 0.1 dB splices, and a 3 dB reserve, total loss is 9 dB, received power is −9 dBm, and the loss-limited reach is 65.71 km.
Assumptions and limits
This simplified power-only budget excludes dispersion, optical path penalties, amplifier noise, reflectance, aging allowances beyond the entered reserve, and equipment overload limits. Use applicable transceiver and system specifications for a design decision.
Frequently asked questions
How is the link loss added?
Fiber attenuation is multiplied by length, then connector and splice losses are added in decibels.
What does the margin mean?
It is received power minus receiver sensitivity; the reserve input is held back when calculating maximum reach.
Does this prove a link will work?
No. Dispersion, path penalties, equipment limits, wavelength, and applicable system rules also matter.
How do I use the Optical Fiber Link Budget Calculator?
Enter Transmitter launch power (dBm), Receiver sensitivity (dBm), Installed fiber length (km), Fiber attenuation (dB/km), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Optical Fiber Link Budget?
For 0 dBm launch power, −28 dBm receiver sensitivity, 20 km at 0.35 dB/km, two 0.5 dB connectors, ten 0.1 dB splices, and a 3 dB reserve, total loss is 9 dB, received power is −9 dBm, and the loss-limited reach is 65.71 km.
Reference: ITU-T G Supplement 39 (2025), optical-system link power-budget methods. See our calculation methodology.