Free and submerged sluice gate discharge comparison calculator

Compare energy-head effects in free and submerged gate discharge using an explicit coefficient and sill-referenced water depths.

4,000 tools
Free and submerged sluice gate discharge comparison calculator — Gate opening width (m), Gate opening height (m), Upstream depth above gate sill (m) and calculation method
Free and submerged sluice gate discharge comparison calculator: inputs and calculation method.

How to use this calculator

Compare energy-head effects in free and submerged gate discharge using an explicit coefficient and sill-referenced water depths.

  1. Enter Gate opening width (m), Gate opening height (m), Upstream depth above gate sill (m), Tailwater depth above sill (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Free and submerged sluice gate discharge comparison explained

Submerged gate estimate2.3038m³/s
Submerged gate estimate: 2.303846 m³/s in the worked scenario.

A numerical walkthrough

Gate opening width (m) = 2; Gate opening height (m) = 0.4; Upstream depth above gate sill (m) = 2; Tailwater depth above sill (m) = 0.9; Specified discharge coefficient = 0.62.

  • Submerged gate estimate: 2.303846 m³/s
  • Free gate estimate using opening-centre head: 2.947089 m³/s
  • Tailwater to upstream depth ratio: 0.45

A 2 m wide, 0.4 m opening with upstream depth 2 m and tailwater 0.9 m uses Cd=0.62. The submerged branch uses a 1.1 m differential head.

The model behind the numbers

Qsub=Cdb a√[2g(Hu−Hd)]; Qfree≈Cdb a√[2g(Hu−a/2)] for the stated opening-centre head approximation.

The two outputs are alternative regime estimates, not simultaneous flows. The calculator does not determine the actual submergence transition from a universal tailwater ratio.

What to enter

b — Gate opening width (m)
Clear gate width across the flow.
a — Gate opening height (m)
Vertical opening height.
H — Upstream depth above gate sill (m)
Upstream hydrostatic depth, greater than the opening height.
Ht — Tailwater depth above sill (m)
Downstream water depth; a submerged comparison requires it to cover the gate opening.
Cd — Specified discharge coefficient
Calibrated or justified contraction/discharge coefficient for the selected gate regime.

Interpreting the result

Quasi-steady incompressible gate flow with user-specified Cd. Vena-contracta geometry, approach velocity and dynamic gate motion are not solved. Educational model; this is not a code-compliant design check.

Reading the outputs

Both flows are m³/s; the tailwater/upstream depth ratio is dimensionless and is descriptive rather than an automatic regime rule.

Frequently asked questions

Which of the two flows should I use?

Use the branch justified by actual hydraulic conditions and a coefficient calibrated for that regime.

Can one Cd be exact in both branches?

Usually not. The shared coefficient is for comparison; site or standard gate calibration should supply applicable values.

Does the ratio automatically tell me submergence?

No. Transition depends on gate contraction and downstream hydraulics, so no universal switch is asserted.

How do I use the Free and submerged sluice gate discharge comparison calculator?

Enter Gate opening width (m), Gate opening height (m), Upstream depth above gate sill (m), Tailwater depth above sill (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Free and submerged sluice gate discharge comparison?

Gate opening width (m) = 2; Gate opening height (m) = 0.4; Upstream depth above gate sill (m) = 2; Tailwater depth above sill (m) = 0.9; Specified discharge coefficient = 0.62. Submerged gate estimate: 2.303846 m³/s Free gate estimate using opening-centre head: 2.947089 m³/s Tailwater to upstream depth ratio: 0.45 A 2 m wide, 0.4 m opening with upstream depth 2 m and tailwater 0.9 m uses Cd=0.62. The submerged branch uses a 1.1 m differential head.